LKH-40 - 25 kW Motor
| | | | | | Motor: | 3500 rpm. synchr. | NOTE! The curves refer to motor: 33.5 Hp (25 kW), 3500 rpm. asynchr., 60 Hz.
For smaller motors, reduce head (H) with: - 3% for 16.8-28.2 Hp (12.5-21 kW). - 5% for 11.5 Hp (8.6 kW). | | Tolerance: | ±5% | | Impeller, Max. dia.: | 9.252” (235 mm) | | Impeller, Min. dia.: | 6.693” (170 mm) | | Pump inlet, Dia.: | 3” (76 mm, DN 80) | | Pump outlet, Dia.: | 2” (51 mm, DN 50) | | | | | | | Performance data refer to water at 68°F (20°C) | DO NOT FORGET THE SAFETY FACTOR. | | | | | |  |
| 00000284
For for more information about our products and services, contact us today!
|